Bad odour generated through microorganism activity or other organic source is an issue that hospitals and hotels need to deal with. Most of the odour is caused by volatile organic compounds (VOC). There are two different methods of odour control: Masking odour control and Reactive odour control.
The Guardian Air QR (GAQr-HVAC) by RGF® , USA is designed to eliminate sick building syndrome risks by reducing odors, air pollutants, VOCs (chemical odors), smoke, mold bacteria and viruses. The HVAC-PHI Cells are easily mounted into air conditioning and heating systems air ducts where most sick building problems start. When the HVAC system is in operation the HVAC-PHI Cell creates an Advanced Oxidation Process consisting of: Hydro-peroxides, super oxide ions and hydroxide ions. All are friendly oxidizers. By friendly oxidizers we mean oxidizers that revert back to oxygen and hydrogen after the oxidation of the pollutant.
Why Use RGF’s Photohydroionization® Technology ?
Germicidal UV light rays have been used for decades by the medical industry as a method for destroying micro-organisms (germs, viruses, bacteria). UV light is dependable and can be easily installed in HVAC ducts or a plenum. Germicidal UV light is effective in reducing only the airborne micro-organisms that pass directly through the light rays. However, germicidal UV light has little to no effect on gases, vapors or odors. Photohydroionization Advanced Oxidation, on the other hand, is very effective on gases, vapors, VOCs and odors in the room at the source of contamination.
The Guardian Air QR+ in-duct air purifier utilizes RGF’s proprietary PHI-CELL® technology. Installed into the supply plenum of your existing air conditioning or heating system air ducts, the Guardian Air QR+ in-duct air purifier produces low level, airborne hydrogen peroxide molecules that are distributed by the air handler, through the duct system and into the conditioned space. Unlike passive air technologies, which need pollutants to pass through the unit for purification or filtration, the Guardian Air QR+ in-duct air purifier sweeps through the air conditioned space actively purifying pollutants at the source.
UV light enhanced by a hydrated quad-metallic compound target develops an advanced oxidation reaction that creates an Advanced Oxidation Proccess This process also produces hydro-peroxides, super oxide ions and hydroxides. By engineering the proper UV light wavelength, in combination with a triple function, no maintenance unit, The PHI Cell provides safe AOP to purify the air. With the RGF HVAC-PHI Cell Advanced Oxidation System, micro-organisms can be reduced by over 95%. Gases, VOCs and odors can also be reduced significantly, and the room will have hydro-peroxides, super oxide ion and hydroxides which will help give your room fresh, clean and odor free air.
Technology RGF’s PhotohydroionizationTM, USA
Installation Installed in HVAC duct or plenum
Dimension 5” to 14"probe, 5.5” dia
HVAC Size 300 to 1200, 6500, 18000 CFM
Voltage (V) 230 / 110 Power (W) 20 to 40
Weight 4 lbs
The Guardian Air Plug In (GAPi-800) Natural Air Purification System provides bacteria, virus, mold, odor and VOCs (chemical odors)reduction. A fully American made product. The advantage of the Guardian Air Plug In is its ability to be used in any room and be completely inconspicuous.The Guardian Air Plug In plugs directly into a wall outlet and can be used with or without its internal fan. Because it has its own outlets as part of the unit, you do not lose the wall outlet. The Guardian Air Plug In is an air treatment system not a filter.
The Problem:
Indoor air pollution is now considered by the EPA and Congress to be one of America’s most seroius environmental health problems. Tightly sealed buildings and homes may be more energy efficient but can trap pollutants and microbes indoors causing allergies odors, mold and illness.
The Solution:
The Guardian Air Plug In by RGF has proven to drastically reduce odors, smoke, mold, fungi, VOCs (chemical odors) and bacteria found in many rooms. Airborne bacteria and mold reduction is normally in the 90+ percentile.
The Technology:
The Guardian Air Plug In utilizes RGF’s PhotohydroionizationTM technology which creates super oxide ions, hydroperoxides, hydroxides and UV light targeted on a hydrated quad-metallic target to develop an advanced oxidation
The RGF Pure Air™ Advantage While UV systems are designed to kill mold on the HVAC coil, the RGF PHI Cell™ does this, plus it adds advanced oxidants throughout the room to kill microbials at the source. The Sneeze Test Simulated Sneeze Lab Test at three feet in a 250 cu ft Bio Test Chamber. 78% reduction.
Technology RGF’s PhotohydroionizationTM, USA
Dimension 6.25” w x 3.75” d x 10” h
Application area (Sq. Ft) 800
Voltage (V) 230 / 110 Power (W) 50
Weight 2 lbs
Noise (dB) Less than 20
Mounting Wall
Highly advanced Face & Palm Verification Terminal featured with Body Temperature Detection functions and Masked-Facial Identification. The device is equipped with a smart facial recognition algorithm and latest computer vision technology for touchless user-identification supported . The series comes with remarkable storage capacity with clear-cut verification of both facial and palm recognition in less than a second.
The device promotes public safety and hygiene through contactless user-identification coupled with body temperature detection and masked-facial recognition. In addition, it is enhanced with powerful anti-spoofing technology against various types of fake photos and video attacks.
The device offers breakthrough performance in reducing the risk of infection and germs spreading in heavily crowded places such as hospitals, industrial areas, schools, IT parks, public transport facilities, etc.
Features:
Techinical Specificatons:
Faces | 30,000 (1:N) / 50,000 (Optional) |
Palm | 5,000 (1:N) |
Users / Cards | 50,000 |
Transactions | 1,000,000 (Optional) / 2,000,000 |
User Photos | 30,000 |
Event Photos | 10,000 |
* Proface X[TD] doesn't support card | |
Compatibility | Security Relay Box / Wiegand / RS485 / RS232 Slave Reader with FP / RFID / Barcode / QR-code / ZKBioSecurity Software |
Hardware | 900MHz Dual Core Customized AI CPU |
512MB RAM / 8G Flash | |
8" Hight light (400lux) IPS Touch LCD | |
125KHz EM Reader / 13.56MHz MF(Optional) | |
2MP WDR Low Light Camera | |
Adjustable Light brightness LED | |
Hi-Fi Voice | |
High Sensitivity Microphone | |
Distance Detection Sensor | |
Reset Button and Tamper Switch | |
Access Control Interface | Lock Relay Output / Alarm Output / Auxiliary Input / Exit Button / Door Sensor |
Special Functions | IP68 & IK04 |
0.3s Hight Speed Facial Verification | |
Liveness Detection | |
HTTPS Communication Encryption (Optional) | |
Event Snapshot | |
Standard Functions |
Access Levels, Groups, Holidays, DST,Duress Mode (Password), Anti-Passback, |
ntiepidemic | Mask detection |
Body temperature detection (ProFace X [TD] Only)
|
|
Temperature Measurement Distance: | 30cm~50cm (1ft~1.64ft) |
Temperature Measurement Accuracy: | ±0.3°C |
Temperature Measurement Range: | 34°C~45°C |
Communication | TCP/IP / Wiegand Input / Output / Wi-Fi (Optional) / RS485 / RS232 |
Additional Info | |
Face Algorithm: | ZKLiveFace5.8 |
Palm: | FAR ≤0.01%; FRR ≤1% |
Working Temperature: | -30°C ~ 60°C,(-22°F ~ 140°F) |
Working Humidity: | ≤93% |
Storage Temperature: | -40°C ~ 65°C |
Storage Humidity: | ≤93% |
Net Weight: | 853g |
Dimensions (H*L*D): | 227*143*26.1mm |
Power | Operating Voltage: 12V DCCurrent Draw: <2,000mA |
Touchless Indoor Speed Gate-based entrance control solution with body temperature detection functions. The device consists of stainless steel body for long-term usage and the barrier panels are made of acrylic for better aging resistance and impact resistance. The barrier is designed to match with indoor architecture and the transparent panels offer an elegant look.
The entrance control system is integrated with advanced facial recognition terminals featured with computer vision technology and smart facial recognition algorithms for masked-facial recognition. In addition, the device combines visible light facial recognition technology with infrared temperature detection for accurate and fast body temperature measurements during user-verification.
The entrance control system can be extremely helpful to facilitate the public in heavily crowded places such as hospitals, industrial areas, schools, public facilities, IT parks, etc as well as in reducing the spread of infections and germs.
Features:
Technical Specification:
Power Requirements |
AC 100 ~ 120V/200 ~ 240V, 50/60Hz |
Working Temperature |
-28°C ~ 60°C |
Working Humidity |
20% - 95% (Non-condensing) |
Working Environment |
Indoor |
Max. Speed of Throughput |
40 people per minute |
Lane Width (mm) |
660 |
Dimensions (L*W*H) |
1600 * 1040 * 1200 (mm) |
Packing Dimensions (L*W*H) |
1700 * 300 * 1130 (mm) |
Net Weight (kg) |
130kg |
Weight with Packing (kg) |
150kg |
Cabinet Material |
SUS304 Stainless Steel |
Lid Material |
SUS304 Stainless Steel & Acrylic |
Barrier Material |
Acrylic |
Barrier Movement |
Swing |
Emergency Mode |
Supported |
Face Capacity |
30,000 (1:N) / 50,000 (Optional) |
Compatibility |
900 MHz Dual Core Customized CPU |
512MB RAM / 8G Flash |
|
8" High Brightness (400lux) IPS Touch LCD |
|
2MP WDR Low Light Camera |
|
IP68 & IK04 |
|
Dimensions of Facial Recognition Device (H*L*D) |
227 * 143 * 26 (mm) |
Facial Recognition Distance of Masked Individuals |
3m |
Temperature Deviation |
+/- 0.5 degrees |
Body Temperature Detection Distance |
25cm – 50cm |
Body Temperature Detection Speed |
>0.3s |
Temperature Selection Posture Angle Tolerance |
+/-30 degrees |
The latest walk-through metal detector with body temperature detection functions. The device consists of robust security features such as 18 detection zones, 256 adjustable sensitivity levels, 5.7" wide LCD display, Synchronous sound with LED alarm as well as an Alarm strength indicator.
The system comes with an inbuilt high-performance infrared temperature sensor for accurate body temperature measurement of users. If the temperature measurement is over 37.3°C, the alarm will get triggered immediately to notify the security guards. The security inspection system can be extremely useful to minimize the spread of infections and can be applied to heavily crowded places such as malls, banks, museums, stadiums, public transport facilities, IT parks, etc. The device scientifically improves public security, safety, and hygiene.
Features:
Technical Specifications
Power supply |
AC100V-240V |
Working temperature |
-20℃~+50℃ |
Working frequency |
4KHz-8KHz |
Standard external size |
2220mm(H)*835mm(W)*578mm(D) |
Standard internal size |
1990mm(H)*700mm(W)*578mm(D) |
Package size for door panels |
2260*650*260mm*1ctn |
Package size for control unit |
780*390*250mm*1ctn |
Gross weight |
70kg |
We implement complicated baggage inspection system with most efficient manner. Our baggage reconciliation system is designed to reflect and adapt to current and future changes in technology and regulations It helps to identify suspicious items such as weapons, liquids, explosives, drugs, knives, fire guns, bombs, toxic substances, flammable substances, ammunition and other dangerous objects which may lead to potential safety hazards by atomic number identification. High image quality in combination with automatic identification of suspicious objects allows the operator to quickly and effectively evaluate any luggage content.
Our unique software help you to analysis the baggage movement from remote location, can also offer a cartelized monitoring for baggage inspector erected in different location.
Software Specifications
Technical Specifications
Tunnel Size |
W507mm*H305mm |
Speed |
0.20m/s |
Hight of Transmission Belt |
1000mm |
Maximum Load |
≤120Kg(Adequate distribution) |
Wire Resolution |
38 AWG(0.1mm metal wire) |
Space Defintion |
HorizontalΦ1.0mm/VerticalΦ2.0mm |
Penetrate Definition |
32 AWG |
Penetration |
32mm Steel board |
Monitor |
17 inch LED |
System Function |
High density alarm, TIP, Luggage counter, System running timer, X-ray emitting timer, System maintainance, Training, 64 times continuous zoom in |
Film Safety |
ASA/ISO1600 standard of film safety |
Tube Voltage |
140kV |
Cooling |
Seal oil cooling/100% |
Single Inspection Dosage Rate |
≤1.0μGy |
Radiation Leak Dosage |
0.1μGy/h(5cm from the shell) |
Package Size |
L1990mm*W990m*H1320mm |
Package Weight |
450KG |
Power Consumption |
1kVA |
Noise |
53.8dB(A) |
Unit |
VBS-30 |
|
Voltage |
V |
220-240 |
Power Consumption |
W |
25 |
Net Weight |
KG |
4.5 |
Dimension |
LxBxH (cm) |
67x15.5x9.5 |
Air Flow |
m3/h/cfm |
7/4 |
Application Space |
Sq.Ft |
150 to 200 |
Unit |
VBS-30 |
|
Voltage |
V |
220-240 |
Power Consumption |
W |
50 |
Net Weight |
KG |
9.5 |
Dimension |
LxBxH (cm) |
87x25x11.5 |
Air Flow |
m3/h/cfm |
18/11 |
Application Space |
Sq.Ft |
300 to 400 |